![]() According to me the first study would be right. ![]() ![]() Out of plane deflections (S i=U i-(1/2U i-2+1/2U i+2)) are not used in the calculations of tank settlement validation. API-653 B.3.2.2 Smax,in and API-653 B.3.2.1 both only give limits to the out-of-plane settlement (Ui) Now after reading the chapter on tank settlement on my own, and making a speadsheet of my own I came to the following conclusion: The second one said that the tank was not within the standard of API-653 (This on was comparing the Si for each and every point collected and comparing it to S max,in as per Art. The first one said everything was fine (This one was comparing Ui for each and every point collected, and comparing it to S max,in as per Art. The results came back and both had different answers: The data was collected by a surveyor and was sent out to two different firms. data, thickness measurements, edge/floor settlement, corrosion areas, etc. I recently got issues concerning a settlement status concerning a API-653 renovated tank. IATs Aboveground Storage Tank Inspection (API 653) Application that allows.